    Product Details:

    Place of Origin: Guangzhou / GuangDong / China
    Brand Name: TSTLP
    Certification: CE Compliance
    Model Number: TS-230M5RM

    Payment & Shipping Terms:

    Minimum Order Quantity: Negotiable
    Price: Negotiable if good quantity
    Packaging Details: By standard export box/carton
    Delivery Time: Around 6 working days upon receipt of full payment
    Payment Terms: 100% T.T. / Western Union / WeChat Transfer / Alipay / Cash in advance
    Supply Ability: 2000 sets/month
    Contact Now
    Detailed Product Description
    Un: 230V Uc Optional: 30V / 60V / 75V / 150V / 320V
    Normal Discharge Current: 5kA Type Of Remote Signalling Contact: Break Contact
    Test Standards: IEC 61643-11 Certified: CE

    24v / 48v / 60v / 120v / 220v / 230v type 3 transient surge suppressor

     

    TS-230M5RM Class III transient surge suppressor is designed as per IEC 61643-11 to install at LPZ 1-2 or higher as fine protection for electronic devices. e.g. icebox, air conditioner, photocopy, communication equipment, network equipment... various power supply system

     

    • Technical Data
    Model No. TS-230M5RM TS-120M5RM TS-60M5RM TS-48M2RM TS-24M2RM
    Normal a.c. Voltage Un 230V 120V 60V 48V 24V
    Rated voltage (max.a.c. continuous voltage) Uc 320V 150V 75V 60V 30V
    Rated voltage (max.d.c. continuous voltage) Uc 320V 150V 75V 60V 30V
    Normal Current IL 16A 16A 16A 16A 16A
    Nominal discharge current (8/20, L-N) In 3 kA 2.5 kA 2.5 kA 1 kA 1 kA
    Nominal discharge current (8/20, L+N-PE) In 5 kA 5 kA 5 kA 2 kA 2 kA
    Combination wave (L-N) Uoc 6 kV 6 kV 6 kV 2 kV 2 kV
    Combination wave (L+N-PE) Uoc 10 kV 10 kV 10 kV 4 kV 4 kV
    Voltage protection level(L-N) Up ≤1.15 kV ≤0.7 kV ≤0.5 kV ≤0.35 kV ≤0.2 kV
    Voltage protection level(L+N-PE) Up ≤1.5 kV ≤1.1 kV ≤0.85 kV ≤0.85 kV ≤0.85 kV
    Response time tA ≤25ns (L-N); ≤100ns(L+N-PE)
    Max. back up fuse 16A gL/gG
    Operating temperature range Tu -40°C...+80°C
    Short-circuit withstand capability at max.backup fuse 6kArms
    Relative humidity: ≤95% (25°C)
    Cross-sectional area 0.5mm2 ~ 6mm2 solid / 4mm2 flexible
    Mounting on 35mm2 DIN rail
    Enclosure material Red thermoplastic, UL94-V0
    Standards IEC 61643-11; GB 18802.1; YD/T 1235.1
    Type of remote signalling contact Break contact
    Switching capacity UN/IN AC:250V/0.5A DC:250V/0.1A,125V/0.2A,75V/0.5A
    Cross-sectional area for remote signalling contact Max. 1.5mm2 solid / flexible
    Compliance CE (LVD, EMC)

     

    • Main Character
    1. Class 3 transient surge suppressor with LIGHT indications: Green - OK, red - Fault
    2. Single-phase surge protection and with disconnector
    3. Remote signalling connector for fault indication
    • INSTALLATION STEPS
    1. Mount the transient surge suppressor on 35 mm DIN rail.
    2. Connect conductors, the cross-sectional area of cable must be larger than 4mm2 . The withstand voltage value of cable is not smaller than AC500V; ensure wiring reliable.
    3. If Remote Alarm needed, it s/b connected signal lines to remote signal terminal 1 and 2 connected.
    4. After above, switch on the power supply and turn on the circuit breaker, if the transient surge suppressor’s indicator light displays green,this indicates the unit is operating normally.

    Regularly inspect the operating status, especially after lightning. Once the fuse upstream breaks, or the transient surge suppressor's indicator light displays red, electrician should check/replace the transient surge suppressor.

     

    • Installation Diagram

    Type 3 Transient Surge Suppressor 24v / 48v / 60v / 120v / 220v / 230v

     

    PDF Catalog Download - TSTLP 24~230V Type 3 SPD.pd...

     

    Tag: transient surge suppressor

    Contact Details
    TS Lightning Protection Co.,Limited

    Contact Person: Franklin

    Tel: +86-13926098193

    Send your inquiry directly to us (0 / 3000)

    Other Products