TS Lightning Protection Co.,Limited

Professional Lightning Protection Manufacturer

Home
Products
About Us
Factory Tour
Quality Control
Contact Us
Request A Quote
Company News
Home ProductsEse Lightning Rod

Early Streamer Emission Ese Lightning Rod On Buildings NF C 17-102 Standard

Early Streamer Emission Ese Lightning Rod On Buildings NF C 17-102 Standard

    • Early Streamer Emission Ese Lightning Rod On Buildings NF C 17-102 Standard
    • Early Streamer Emission Ese Lightning Rod On Buildings NF C 17-102 Standard
    • Early Streamer Emission Ese Lightning Rod On Buildings NF C 17-102 Standard
    • Early Streamer Emission Ese Lightning Rod On Buildings NF C 17-102 Standard
  • Early Streamer Emission Ese Lightning Rod On Buildings NF C 17-102 Standard

    Product Details:

    Place of Origin: Guangzhou / GuangDong / China
    Brand Name: TSTLP
    Certification: Patent / CE
    Model Number: SMT-ESE30

    Payment & Shipping Terms:

    Minimum Order Quantity: Negotiable
    Price: Negotiable if good quantity
    Packaging Details: 230x230x450mm colorful box/pc, and 4 pcs in 490x500x500mm carton
    Delivery Time: Around 6 working days upon receipt of full payment
    Payment Terms: 100% T.T / Western Union / WeChat Transfer / Alipay / Cash in advance
    Supply Ability: 1000 pcs/month
    Contact Now
    Detailed Product Description
    Name: Early Streamer Emission Lightning Rod Efficiency: 30 Microsecond In Advance
    Iimp Withstanding Test: 100kA Iimp Required Lightning Current Withstanding: 200kA
    Standards: NF C 17-102:2011 Weight: 3.0kg
    Max Rp: 90m HS Code: 85354000.00

    TSTLP Early Streamer Emission Lightning Rod On Buildings As Per NF C 17-102 Standard

     

    Early Streamer Emission Ese Lightning Rod On Buildings NF C 17-102 Standard

     

    • TSTLP Early Streamer Emission Lightning Rod's Working Principle

    Early Streamer Emission Ese Lightning Rod On Buildings NF C 17-102 Standard

     

    1. Lower electrodes of TSTLP early streamer emission lightning rod gather energy from naturally occurring ambient electrical fields that increase as much as ten thousand volts per meter as the storm approaches.
    2. TSTLP early streamer emission lightning rod collects the electrical energy and stores in capacitors inside the TSTLP ESE. Just before a lightning strike the atmospheric electrical field increases rapidly,activating the patented triggering device.
    3. TSTLP early streamer emission lightning rod’s trigger releases the stored energy in the capacitors through the upper electrodes at the tip of the air terminal and initiates an upward leader at the optimum moment.
    4. Upward leader that TSTLP early streamer emission lightning rod produces connects with the downward leader and the result is a lightning strike that directed safely to ground through the air terminal, downleads, and grounding system.

     

    • Technical Data
    TSTLP ESE lightning rod models SMT-ESE30
    Patent No. 2013300191363
    Efficiency (ΔT) 30μs
    Standard Deviation ESE / Single Rod σ σESE < 0.6 σPTS
    Lightning current withstanding test Iimp 100kA (normative test at 10/350μs waveform as standard requires)
    Lightning current withstanding Iimp ≥ 200kA (10/350)
    Capacity against wind speed ≥40m/s
    Dimension(Length) 418 mm
    Approx net weight 3.0kg
    Enclosure material Superior Quality Stainless Steel
    Test Standards NF C 17-102_2011 Annexe C
    UNE 21.186:2011 Paragraph C
    IEC 60060-1:2010 Part 1
    EN 60060-1:2010
    GB/T T16927.1-2011 Part 1;

     

    • SMT-ESE30 early streamer emission lightning rod MECHANICAL SPECS
    Fixed on elevation pole M20 Thread
    Down conductor connection Specific tape/cable clamp
    PACKING IN DETAIL
    Dimensions 230*230*450 mm box/pc, 4pcs in 480*500*500mm carton
    Packing Contents TSTLP® E.S.E. early streamer emission lightning rod Head, Nut, Hex key;
    Approx GT (kg) 4
    Environmental sustainability 100% recyclable

     

    • Radius Protection Table of TSTLP SMT-ESE30 Early Streamer Emission Lightning Rod

    Early Streamer Emission Ese Lightning Rod On Buildings NF C 17-102 Standard

     

    • TSTLP Early Streamer Emission Lightning Rods On Building Protection

    Installation procedure for TSTLP ESE Lightning Rod is governed by latest French standard NF C 17-102 and follows a series of simple rules catering for all types of structure;(Referring to installation stated in French standard NF C 17-102_2011)

     

    Early Streamer Emission Ese Lightning Rod On Buildings NF C 17-102 Standard

    • Part stock of TSTLP Early Streamer Emission Ese Lightning Rods

    Early Streamer Emission Ese Lightning Rod On Buildings NF C 17-102 Standard

     

    • Installation Photos

    Early Streamer Emission Ese Lightning Rod On Buildings NF C 17-102 Standard

     

    PDF Catalog Download - TSTLP SMT-ESE30 Datasheet.p...

     

    Tag: early streamer emission lightning rod, lightning rods on buildings

    Contact Details
    TS Lightning Protection Co.,Limited

    Contact Person: Franklin

    Tel: +86-13926098193

    Send your inquiry directly to us (0 / 3000)

    Other Products