Internationally Tested Self Active Ese Lightning Rod 60μS Long Life

Internationally Tested Self Active Ese Lightning Rod 60μS Long Life

Internationally Tested Self Active Ese Lightning Rod 60μS Long Life

Product Details:

Place of Origin: Baiyun - Guangzhou, Guangdong - China - Asia
Brand Name: TSTLP
Certification: ISO 9001:2015 / CE / Patent Right / Official Test Reports fm Europe / Shanghai / Shenzhen
Model Number: SMT-ESE60

Payment & Shipping Terms:

Minimum Order Quantity: 4pc (1st order< 4pc is OK)
Price: Negotiable if good quantity
Packaging Details: 230x230x450mm colorful box/pc, and 4 pcs in 490x500x500mm carton
Delivery Time: Around 7 working days upon receipt of TT payment
Payment Terms: 100% TT / LC / Western Union / MoneyGram / WeChat Transfer / Alipay / Wanda Money Transfer / Cash in advance
Supply Ability: 1,000 pcs/month
Contact Now
Detailed Product Description
Type Name: ESE Lightning Rod Delta T: 60μs
Withstanding Test Required Iimp As Standard: 100kA Iimp Withstanding: ≥200kA (10/350μs Waveform)
Test Standards: NF C 17-102:2011 Annexe C & UNE 21.186:2011 Paragraph C; IEC 60060-1:2010 Part 1; EN 60060-1:2010 Accredited Labs: Shanghai / Shenzhen / Spain & Romania - Europe
Net Weight(kg): 4.0 Lightning Rod HS Code: 8535400000

Popular Home & Overseas Tested TSTLP Self-Active Ese Lightning Rod ( also referred as ESE lightening rod or early streamer emission lightning rod ) for external/direct lightning protection system - Reliable & Long Life.

  • ADVANTAGES
  1. Patent available, GREAT for promotion & interests protection.
  2. Successfully tested according to NF C 17-102:2011 Annexe C & UNE 21.186:2011 Paragraph C at ACCREDITED High-Voltage Laboratories in  Europe, Shanghai & Shenzhen as well as CE certificate for your full satisfaction. (Test Reports with CE, CMA & CAL,  Romania-RENAR, Spainish ENAC & ilac-MRA remarks available) for Medium-High-End World Markets.
  3. TSTLP Ese Lightning Rod only becomes active when electrical field intensity rises & TSTLP early streamer emission lightning rod presents no danger to the objects protected.
  4. Reliable, Durable after withstanding different lightning strikes even in extreme climatic conditions.
  5. Maintenance-Free.
  6. ISO 9001:2015 Quality Certified Manufacturing Process, strict multiple LOOP & Sparking Tests by advanced TSTLP ESE Testers

Internationally Tested Self Active Ese Lightning Rod 60μS Long Life

  • TSTLP Early Streamer Emission Lightning Arrester's Working Principle ( How does TSTLP ESE lightning rod work ? )

Internationally Tested Self Active Ese Lightning Rod 60μS Long Life

 

  1. The IONIZATION SYSTEM IS CHARGED - via the lower electrodes using the ambient electrical field (several thousand volts/meter when storms are approaching),which means TSTLP Ese Lightning Rod is a fully autonomous system requiring no external power supply.
  2. ACTIVATING THE NEW TSTLP TECHNOLOGY - Whilst dynamically assessing the development of the surrounding electrical field, the TSTLP ESE detects the appearance of downward leaders. This innovative and patented TSTLP ESE system is then activated to neutralize the space charges, which naturally occur around the air terminal. The TSTLP ESE Lightning Rod is ready to operate in an optimal environment
  3. CONTROLLING THE IONIZATION PROCESS - The ambient electrical field increases rapidly when a discharge is imminent and a downward leader decens from cloud to ground. This triggers the ionization process, using a spark ionization system between the upper electrodes and the central tip. The TSTLP ESE Lightning Rod reacts at the precise moment, when the risk of lightning discharge is imminent.
  4. ​EARLY TRIGGERING OF THE UPWARD LEADER - The controlled ionization process and the new TSTLP technology guarantee the triggering of an upward leader ahead of any other protruding point within the area to be protected making the TSTLP ESE Lightning Rod be the preferential point of impact for the lightning discharge and provides the structure with maximum protection.

 

 
  • Comparing TSTLP ESE Air Terminal with ordinal/simple one

Internationally Tested Self Active Ese Lightning Rod 60μS Long Life
 

  • TSTLP / SMT-ESE60 Early Streamer Emission Lightning Conductor Technical Data
Product models SMT-ESE60
Patent Right Available as request
Delta T 60 microsecond
Standard Deviation ESE / Single Rod σ σESE < 0.4 σPTS

Lightning current withstanding test

Iimp (10/350μs)

100kA (normative test as per standard)
Lightning current withstanding Iimp ≥ 200,000A (10/350 μs)
Capacity against wind speed ≥144 km/h
Dimension(Length: cm) 40.8
Approx net weight (g) 4000
Enclosure material High Quality Stainless Steel
Test Standards / References NF C 17-102:2011 Annexe C standard
NF C 17-108 standard / IEC 62305 compliant
UNE 21.186:2011 Paragraph C standard
IEC 60060-1:2010 Part 1 standard
EN 60060-1:2010 standard
GB/T T16927.1:2011 Part 1 standard

 

MECHANICAL SPECIFICATIONS of TSTLP SMT-ESE60 ese lightning rod
Fixing on pole M20 Thread
Down conductor connection Specific clamp
PACKING
Dimensions 230*230*450 mm box/set, 4 sets in 480*490*490mm carton
Packing Contents TSTLP® E.S.E. lightning rod Head, Nut, Hex key;
Approx Gross Weight 5.5 kg
Environmental sustainability Completely recyclable

 
Internationally Tested Self Active Ese Lightning Rod 60μS Long Life

  • RADIUS PROTECTION

The protection radius of TSTLP Ese Lightning rod is related to its height (h) relative to the surface to be protected, to its efficiency and to the selected protection level
for h ≥ 5 m; and
Internationally Tested Self Active Ese Lightning Rod 60μS Long Life
Rp = h × Rp(5)/5 for 2 m ≤ h ≤ 5 m
Rp (h) (m): is the protection radius at a given height h
h (m) : is the height of the ESE lightning rod tip over the horizontal plane through the furthest point of the object to be protected
 
r (m) : 20 m for protection level I
30m for protection level II
45m for protection level III
60m for protection level IV
 
Δ (m)  = ΔT x 106
Field experience has proved that Δ is equal to the efficiency obtained during the ESE lightning rod evaluation tests
 

  • Radius Protection-TSTLP Early Streamer Emission (ESE) lightning arrester coverage area as per different protection levels

Internationally Tested Self Active Ese Lightning Rod 60μS Long Life

5m installation height is the standard installation height - mostly used by clients

 

Max Radius Protection of TSTLP SMT-ESE60 as per different protection levels:

Level 1:   80 meters radius coverage.

Level 2:   90 meters radius coverage.

Level 3: 105 meters radius coverage.

Level 4: 120 meters radius coverage.


It's highly recommended that Protection Level 1 to be used as highest protection for the objects protected, which most clients do the same.


The protection levels I, II, III or IV (as calculated in NF C 17-108 or EN62305-2) and the height of the TSTLP ESE lightning rod blow the structure to be protected
(H, defined by NF C 17-102 as a minimum 2m).
 
Internationally Tested Self Active Ese Lightning Rod 60μS Long Life
 

  • ESE Lightning Rod Protection of high rise buildings (height greater than 60 m)

Additional protection against direct lightning strike for the highest 20% of the structure height for buildings greater than 60 m or any point above 120 m, using ESE lightning rod or any other means must be implemented at each façade wall according to a valid standard. Furthermore a minimum of 4 Down conductors, interconnected by a ring conductor when applicable, shall be used, distributed along the perimeter and if possible at each angle of the building.
NOTE: in general the risk due to the lateral flashes is low because only a few percent of all flashes to tall structures will be to the side and moreover their parameters are a lot lower than those of flashes to the top of structures.

 

  • Order & Packing

Internationally Tested Self Active Ese Lightning Rod 60μS Long Life
 

  • TSTLP/SMT-ESE60 Early Streamer Emission Air Terminal for miliary airport direct lightning protetion in Europe

Internationally Tested Self Active Ese Lightning Rod 60μS Long Life

 

  • TSTLP/SMT-ESE60 ese lightning rod for KH project "Tiger Show" lightning strike protection.

Internationally Tested Self Active Ese Lightning Rod 60μS Long Life

 

More Overseas Project Referenceshttp://www.tslpro.com/references-4.html

 

Internationally Tested Self Active Ese Lightning Rod 60μS Long Life

 

FAQ:

1 - Is your company manufacturer or distributor or tradig company ?

   - Instead of lightning rod distributors / trading company, we're professional & reliable Surge Protection Device

     ESE Lightning Rod Manufacturer.

 

2 - Is TSTLP your brand ?

   - Yes, TSTLP is our official brand.

 

3 - Can I trust your factory & products ?

A: Sure, we’re ISO 9001:2015 HIGH-Quality Management System Certified Lightning Surge Protection Manufacturer in Guangzhou, China

B: We’re using company bank accounts for receiving international payment and company e-mails for communications for high reliability.

C: We have great MANY real OVERSEAS project/installation references, which c/b tracked on line from our website.

D: Patented & tested by Offical Accredited (High-Voltage) Laboratories, Authorized Test Reports / Certificates available.

E: You’re welcome to visit our factory.


Download PDF TSTLP ESE Lightning Rod Catalog @ https://drive.google.com/file/d/1sHzPnbVjZLkIAeXGNRp4bKSoYsNoqf1C/view?usp=sharing

 

PDF Catalog Download - TSTLP SMT-ESE60 Datasheet.p...
 

PDF Catalog Download - TSTLP-ESE Tester (Black).pd...

 

PDF Catalog Download - Portable TSTLP-ESE Tester....


Relative Product Name: ese lightning conductor, ese air terminal, ese lightning arrester