TS Lightning Protection Co.,Limited

Professional Lightning Protection Manufacturer

Home
Products
About Us
Factory Tour
Quality Control
Contact Us
Request A Quote
Company News
Home ProductsEse Air Terminal

40 μs Triggering Time Controlled ESE Air Terminal For Lightning Protection

40 μs Triggering Time Controlled ESE Air Terminal For Lightning Protection

    • 40 μs Triggering Time Controlled ESE Air Terminal For Lightning Protection
    • 40 μs Triggering Time Controlled ESE Air Terminal For Lightning Protection
  • 40 μs Triggering Time Controlled ESE Air Terminal For Lightning Protection

    Product Details:

    Place of Origin: Guangzhou / GuangDong / China
    Brand Name: TSTLP
    Certification: CE approval / Patent
    Model Number: SMT-ESE40/P

    Payment & Shipping Terms:

    Minimum Order Quantity: Negotiable
    Price: Negotiable if good quantity
    Packaging Details: 230x230x450mm colorful box/pc, and 4 pcs in 490x500x500mm carton
    Delivery Time: Around 6 working days upon receipt of payment
    Payment Terms: 100% T.T / LC / Western Union / MoneyGram / WeChat Transfer / Alipay / Wanda Money Transfer / Cash in advance
    Supply Ability: 1000 pcs/month
    Contact Now
    Detailed Product Description
    Name: Ese Air Terminal Triggering Time: 40 Microsecond
    Enclosure Material: 304SS Iimp Lightning Current Withstanding: 200kA
    Ref Standards: NF C 17-102:2011 Weight(g): 3500

    TSTLP SMT-ESE40 controlled ese air terminal for lightning protection

     

    40 μs Triggering Time Controlled ESE Air Terminal For Lightning Protection

    • Special Technical Parameters

    40 μs Triggering Time Controlled ESE Air Terminal For Lightning Protection

     

    SMT-ESE40 ese air terminal for lightning protection
    Patent Right Available on request
    CE Certifications Nr WTS16030019S (Ref Standard EN 60060-1:2010)
    Relevant STANDARDS
    NF C 17-102:2011
    UNE 21.186:2011
    IEC 60060-1:2010
    GB/T T16927.1-2011

     

    • SMT-ESE40 Radius Protection as per different protection levels 

    40 μs Triggering Time Controlled ESE Air Terminal For Lightning Protection

     

    For each of the lightning protection levels, a minimum current level to be protected against has been determined (selected). Table 5 details these current levels, together with probability percentages that lightning may be greater than these levels. For example, Lightning Protection Level I positions terminals such that 99% of all lightning flashes are intercepted (all those of 3 kA or greater). There is only a 1% probability that lightning may be smaller than the 3 kA minimum, and may not be close enough to an air-terminal to be intercepted. It should be noted that flashes of less than 3 kA are rare, and typically would not be expected to cause damage to the structure. Protection greater than Lightning Protection Level I (99%) would require significantly more material, is not covered by the standard and generally is not required for commercial construction.

     

    Minimum current levels (related to interception efficiency) for lightning protection levels 1 to 4

    Protection Levels LEVEL 1 LEVEL 2 LEVEL 3 LEVEL 4
    Minimum current (kA) 3 5 10 16

    Probability current is greater

    than minimum (%)

    99 97 91 84
    Rolling sphere radius (m) 20 30 45 60

    The lower lightning protection levels (LPL 2 , 3 & 4) each increase the air terminal spacing, reducing their ability to capture smaller lightning flashes, thus reducing overall the percentage of lightning events they can protect against.

     

    • TSTLP ESE Air Terminal Protection of high rise buildings (height greater than 60 m)

    Additional protection against direct lightning strike for the highest 20% of the structure height for buildings greater than 60 m or any point above 120 m, using ESE Air Terminal or any other means must be implemented at each façade wall according to a valid standard. Furthermore a minimum of 4 Down conductors, interconnected by a ring conductor when applicable, shall be used, distributed along the perimeter and if possible at each angle of the building.

    NOTE: in general the risk due to the lateral flashes is low because only a few percent of all flashes to tall structures will be to the side and moreover their parameters are a lot lower than those of flashes to the top of structures.

     

    • SMT-ESE40 ese air terminal for lightning protection installation photo

    40 μs Triggering Time Controlled ESE Air Terminal For Lightning Protection

     

    PDF Catalog Download - TSTLP SMT-ESE40 Datasheet.p...

     

    Tag: ese air terminal, air terminal for lightning protection

    Contact Details
    TS Lightning Protection Co.,Limited

    Contact Person: Franklin

    Tel: +86-13926098193

    Send your inquiry directly to us (0 / 3000)