Start Future From Safety
NO LIGHTNING ACCIDENT IS ALLOWED
Place of Origin: | Guangdong, P.R.C. |
Brand Name: | TSTLP |
Certification: | ISO 9001:2015 Q.M.S. / CE / Patent Right / Official Test Reports fm Spain / Romania / Shanghai / Shenzhen |
Model Number: | SMT-ESE60 |
Minimum Order Quantity: | 4pc (1st order< 4pc is OK for 1st cooperation) |
---|---|
Price: | Negotiable if good quantity |
Packaging Details: | 230x230x450mm colorful box/pc, and 4 pcs in 490x500x500mm carton |
Delivery Time: | Around 5 working days upon receipt of payment |
Payment Terms: | 100% TT / LC / Western Union / MoneyGram / WeChat Transfer / Alipay / Wanda Money Transfer / Cash in advance |
Supply Ability: | 1,200 pieces/month |
Type Name: | ESE Lightning Rod | Delta T: | 60μs |
---|---|---|---|
Withstanding Test Required Iimp As Standard: | 100kA | Iimp Withstanding: | ≥200kA (10/350μs Waveform) |
Max. Radius Protection: | 120m As Per NF C 17-102 Standard | Test Standards: | NF C 17-102:2011 Annexe C & UNE 21.186:2011 Paragraph C; UNE-EN 62561; IEC 60060-1:2010 Part 1;IEC 60068-2-78:2012;IEC 60068-2-52:2017; EN 60060-1:2010;SR EN ISO 6988:1977;GB/T T16927.1-2011 Part 1 |
Accredited Labs: | Shanghai / Shenzhen / Spain & Romania - Europe | Net Weight(kg): | 4.0 |
Lightning Rod HS Code: | 8535400000 | ||
High Light: | lightning arrester rod,early streamer lightning arrester |
Popular Home & Overseas SUCCESSFULLY Tested TSTLP Self-Active Ese Lightning Rod ( also referred as ESE lightening rod or early streamer emission lightning rod ) for external/direct lightning protection system - Reliable & Longlife time.
Product model | SMT-ESE60 |
Patent Right | Available as request |
Delta T | 60 μs |
Standard Deviation ESE / Single Rod σ | σESE < 0.4 σPTS |
Lightning current withstanding test Iimp (10/350μs) |
100kA (normative test as per standard) |
Lightning current withstanding Iimp | ≥ 200 kA (10/350 μs) |
Capacity against wind speed | ≥144km/h |
Dimension(Length: cm) | 40.8 |
Approx net weight (g) | 4000 |
Enclosure material | High Quality Stainless Steel |
Test / Reference Standards | NF C 17-102:2011 Annexe C standard |
NF C 17-108 standard / IEC 62305 compliant | |
UNE 21.186:2011 Paragraph C standard UNE-EN 62561 Standard |
|
IEC 60060-1:2010 Part 1 standard | |
IEC 60068-2-78:2012 | |
IEC 60068-2-52:2017 | |
EN 60060-1:2010 standard | |
SR EN ISO 6988:1977 | |
GB/T T16927.1:2011 Part 1 standard |
MECHANICAL SPECIFICATIONS of TSTLP SMT-ESE60 active ese lightning rod | |||||
Fixing on pole | M20 Thread | ||||
Down conductor connection | Specific clamp | ||||
PACKING | |||||
Dimensions | 230*230*450 mm box/set, 4 sets in 480*490*490mm carton | ||||
Packing Contents | TSTLP® E.S.E. lightning rod Head, Nut, Hex key; | ||||
Approx Gross Weight | 5.5 kg | ||||
Environmental sustainability | Completely recyclable |
The protection radius of TSTLP Ese Lightning rod is related to its height (h) relative to the surface to be protected, to its efficiency and to the selected protection level
for h ≥ 5 m; and
Rp = h × Rp(5)/5 for 2 m ≤ h ≤ 5 m
Rp (h) (m): is the protection radius at a given height h
h (m) : is the height of the ESE lightning rod tip over the horizontal plane through the furthest point of the object to be protected
r (m) :
20 m for protection level I
30m for protection level II
45m for protection level III
60m for protection level IV
Δ (m) = ΔT x 106
Field experience has proved that Δ is equal to the efficiency obtained during the ESE lightning rod evaluation tests
5m installation height is the standard installation height - mostly used by clients
Max Radius Protection of TSTLP SMT-ESE60 as per different protection levels:
Level 1: 80 meters radius coverage.
Level 2: 90 meters radius coverage.
Level 3: 105 meters radius coverage.
Level 4: 120 meters radius coverage.
It's highly recommended that Protection Level 1 to be used as highest protection for the objects protected, which most clients do the same.
The protection levels I, II, III or IV (as calculated in NF C 17-108 or EN62305-2) and the height of the TSTLP ESE lightning rod blow the structure to be protected
(H, defined by NF C 17-102 as a minimum 2m).
Additional protection against direct lightning strike for the highest 20% of the structure height for buildings greater than 60 m or any point above 120 m, using ESE lightning rod or any other means must be implemented at each façade wall according to a valid standard. Furthermore a minimum of 4 Down conductors, interconnected by a ring conductor when applicable, shall be used, distributed along the perimeter and if possible at each angle of the building.
NOTE: in general the risk due to the lateral flashes is low because only a few percent of all flashes to tall structures will be to the side and moreover their parameters are a lot lower than those of flashes to the top of structures.
More Overseas Project References: http://www.tslpro.com/references-4.html
FAQ:
1 - Is your company manufacturer or distributor or tradig company ?
- Instead of lightning rod distributors / trading company, we're professional & reliable Surge Protection Device &
ESE Lightning Rod Manufacturer.
2 - Is TSTLP your brand ?
- Yes, TSTLP is our official registered brand .
3 - Can I trust your factory & products ?
A: Sure, we’re ISO 9001:2015 HIGH-Quality Management System Certified Lightning Surge Protection Manufacturer in Guangdong, China
B: We’re using company bank accounts for receiving international payment and company e-mails for communications for high reliability.
C: We have great MANY real OVERSEAS project/installation references, which c/b tracked on line from our website.
D: Patented & tested by Offical Accredited (High-Voltage) Laboratories, Authorized Test Reports / Certificates available.
E: You’re welcome to visit our factory.
4- I saw some model num or discharge time from others in their website is higher, why your biggest model shows 60μs ?
TSTLP SMT-ESE60's Delta T tested in Shanghai is 66.33μs and ΔT = 64.9 ± 4.6% at ICMET in Romania - Europe.
According to latest standard NF C 17-102:2011, for tested results of ΔT higher than 60μs, the early streamer emission time will be considered as ΔT = 60μs
5 - Why choose our TSTLP ESE lightning rod ?
A: ISO 9001:2015 HIGH-Quality Management System Certified Lightning Protection Manufacturer.
B: Patent Rights Available, unique for promotion & interests protection.
C: Successfully tested at ACCREDITED labs in Shanghai, Spain & Romania - Europe according to the popular French NF C 17-102:2011 Annexe C & Spanish UNE 21.186:2011 standards for your full satisfaction. Cover Pages of Test Reports with CE, CMA & CAL, Romania-RENAR, Spainish ENAC & ilac-MRA marks (ilac-MRA is the most important recognition for international acceptance). TSTLP ESE Lightning Rods ~ No.1 among domestic brands, TOP 10 worldwide
As far as we're concerned, among all the domestic ESE products, ONLY brand TSTLP Active ESE Lightning Rod has passed above mentioned standards (especially for the E.S.E. Time Test) in Accredited Labs in Shanghai & Europe, while Beijing Test Labs are NOT accredited by CMA/CAL/CNAS/ilac-MRA to do above mentioned popular standards..
Download PDF 2021 TSTLP ESE Lightning Rod Catalog @ https://drive.google.com/file/d/1Ok_HQ03COLvV4JhIK3ijjUv2-RYUNbfK/view?usp=sharing
PDF 2021 Datasheet DOWNLOAD - TSTLP SMT-ESE60.pdf
PDF Catalog Download - TSTLP-ESE Tester (Black).pd...
PDF Catalog Download - Portable TSTLP-ESE Tester....
Relative Product Name: ese lightning conductor, ese air terminal, ese lightning arrester
Contact Person: Franklin
Tel: +86-13926098193
Fax: 86-20-28819702-27806
Internationally Tested Self Active Ese Lightning Rod 60μS Long Life
Material - Tested Active Ese Lightning Rod As Per UNE21.186 Mirror - Shine Housing
Rustproof Air Terminal Ese Lightning Arrester For Homes / Barn / Villa / Chimney
Early Streamer Emission Ese Lightning Rod On Buildings NF C 17-102 Standard
120kA Type Surge Protection Device CE Compliance For Electrical Switchboards
CE Approved 100kA Type 1 Surge Protection Device For Electrical Panel Protection
TTY / V11 / RS232 / RS485 / RS422 Surge Protection Device Fire Alarm Surge Protection
Data 4 20mA Surge Protection Device 5v - 110v Available 12x64.5x92mm
CE Approval 7 Digits Lightning Strike Counter Exchangeable 3V Battery Support
Stable 3 Digits ESE Lightning Strike Counter Complies With CE Certificate
Long Life Digital Display Lightning Strike Counter Easy Installation
Power Backup 4 Digits Lightning Stroke Counter With Power Line Surge Protector