Product Details:
Place of Origin: Guangdong, P.R.C.
Brand Name: TSTLP
Certification: ISO 9001:2015 Q.M.S. / CE / Patent Right / Official Test Reports fm Spain / Romania / Shanghai / Shenzhen
Model Number: SMT-ESE60
Payment & Shipping Terms:
Minimum Order Quantity: 4pc (1st order< 4pc is OK for 1st cooperation)
Price: Negotiable if good quantity
Packaging Details: 230x230x450mm colorful box/pc, and 4 pcs in 490x500x500mm carton
Delivery Time: Around 5 working days upon receipt of payment
Payment Terms: 100% TT / LC / Western Union / MoneyGram / WeChat Transfer / Alipay / Wanda Money Transfer / Cash in advance
Supply Ability: 1,200 pieces/month
Contact Now
Detailed Product Description
Type Name: ESE Lightning Rod Delta T: 60μs
Withstanding Test Required Iimp As Standard: 100kA Iimp Withstanding: ≥200kA (10/350μs Waveform)
Max. Radius Protection: 120m As Per NF C 17-102 Standard Test Standards: NF C 17-102:2011 Annexe C & UNE 21.186:2011 Paragraph C; UNE-EN 62561; IEC 60060-1:2010 Part 1;IEC 60068-2-78:2012;IEC 60068-2-52:2017; EN 60060-1:2010;SR EN ISO 6988:1977;GB/T T16927.1-2011 Part 1
Accredited Labs: Shanghai / Shenzhen / Spain & Romania - Europe Net Weight(kg): 4.0
Lightning Rod HS Code: 8535400000
High Light:

lightning arrester rod

,

early streamer lightning arrester

Popular Home & Overseas SUCCESSFULLY Tested TSTLP Self-Active Ese Lightning Rod ( also referred as ESE lightening rod or early streamer emission lightning rod ) for external/direct lightning protection system - Reliable & Longlife time.

 

Internationally Tested Self Active Ese Lightning Rod 60μS Long Life 0

  • ADVANTAGES
  1. Patent available, GREAT for promotion & interests protection.
  2. SUCCESSFULLY tested at ACCREDITED High-Voltage Labs in Shenzhen, Shanghai, Spain & Romania- Europe for your full satisfaction. Cover pages of our authorized Test Reports are marked with CE, CMA, CAL, ENAC, Romania-RENAR & ilac-MRA (ilac-MRA is the most important recognition for international acceptance).                                                                                        TSTLP ESE Lightning Rods ~ No.1 domestically, ONE of the TOP ESE brands worldwide !
  3. TSTLP Ese Lightning Rod only becomes active when electrical field intensity rises & TSTLP early streamer emission lightning rod presents no danger to the objects protected.
  4. Reliable, Durable after withstanding different lightning strikes even in extreme climatic conditions.
  5. Maintenance-Free.
  6. ISO 9001:2015 Q.M.S. Certified Manufacturing Process, strict multiple LOOP & Sparking Tests by advanced TSTLP ESE Testers

Internationally Tested Self Active Ese Lightning Rod 60μS Long Life 1

Internationally Tested Self Active Ese Lightning Rod 60μS Long Life 2

Internationally Tested Self Active Ese Lightning Rod 60μS Long Life 3

  • TSTLP Early Streamer Emission Lightning Arrester's Working Principle ( How does TSTLP ESE lightning arrester work ? )

Internationally Tested Self Active Ese Lightning Rod 60μS Long Life 4

 

  1. The IONIZATION SYSTEM IS CHARGED - via the lower electrodes using the ambient electrical field (several thousand volts/meter when storms are approaching),which means TSTLP Ese Lightning Rod is a fully autonomous system requiring no external power supply.
  2. ACTIVATING THE NEW TSTLP TECHNOLOGY - Whilst dynamically assessing the development of the surrounding electrical field, the TSTLP ESE detects the appearance of downward leaders. This innovative and patented TSTLP ESE system is then activated to neutralize the space charges, which naturally occur around the air terminal. The TSTLP ESE Lightning Rod is ready to operate in an optimal environment
  3. CONTROLLING THE IONIZATION PROCESS - The ambient electrical field increases rapidly when a discharge is imminent and a downward leader decens from cloud to ground. This triggers the ionization process, using a spark ionization system between the upper electrodes and the central tip. The TSTLP ESE Lightning Rod reacts at the precise moment, when the risk of lightning discharge is imminent.
  4. ​EARLY TRIGGERING OF THE UPWARD LEADER - The controlled ionization process and the new TSTLP technology guarantee the triggering of an upward leader ahead of any other protruding point within the area to be protected making the TSTLP ESE Lightning Rod be the preferential point of impact for the lightning discharge and provides the structure with maximum protection.

 

 
  • Comparing TSTLP ESE Air Terminal with ordinal/simple one

Internationally Tested Self Active Ese Lightning Rod 60μS Long Life 5
 

  • TSTLP / SMT-ESE60 Early Streamer Emission Lightning Conductor Technical Data
Product model SMT-ESE60
Patent Right Available as request
Delta T 60 μs
Standard Deviation ESE / Single Rod σ σESE < 0.4 σPTS

Lightning current withstanding test

Iimp (10/350μs)

100kA (normative test as per standard)
Lightning current withstanding Iimp ≥ 200 kA (10/350 μs)
Capacity against wind speed ≥144km/h
Dimension(Length: cm) 40.8
Approx net weight (g) 4000
Enclosure material High Quality Stainless Steel
Test / Reference Standards  NF C 17-102:2011 Annexe C standard
NF C 17-108 standard / IEC 62305 compliant

UNE 21.186:2011 Paragraph C standard

UNE-EN 62561 Standard

IEC 60060-1:2010 Part 1 standard
IEC 60068-2-78:2012
IEC 60068-2-52:2017
EN 60060-1:2010 standard
SR EN ISO 6988:1977
GB/T T16927.1:2011 Part 1 standard

 

MECHANICAL SPECIFICATIONS of TSTLP SMT-ESE60 active ese lightning rod
Fixing on pole M20 Thread
Down conductor connection Specific clamp
PACKING
Dimensions 230*230*450 mm box/set, 4 sets in 480*490*490mm carton
Packing Contents TSTLP® E.S.E. lightning rod Head, Nut, Hex key;
Approx Gross Weight 5.5 kg
Environmental sustainability Completely recyclable

 
Internationally Tested Self Active Ese Lightning Rod 60μS Long Life 6

With 5 years warranty, thanks to our unique design & technology, TSTLP ® provides its users with an extra-long
lifetime - 10 years.
  • RADIUS PROTECTION

The protection radius of TSTLP Ese Lightning rod is related to its height (h) relative to the surface to be protected, to its efficiency and to the selected protection level
for h ≥ 5 m; and
Internationally Tested Self Active Ese Lightning Rod 60μS Long Life 7
Rp = h × Rp(5)/5 for 2 m ≤ h ≤ 5 m
Rp (h) (m): is the protection radius at a given height h
h (m) : is the height of the ESE lightning rod tip over the horizontal plane through the furthest point of the object to be protected
 
r (m) :

20 m for protection level I
30m for protection level II
45m for protection level III
60m for protection level IV
 
Δ (m)  = ΔT x 106
Field experience has proved that Δ is equal to the efficiency obtained during the ESE lightning rod evaluation tests
 

  • Radius Protection - TSTLP Early Streamer Emission (ESE) lightning rod coverage area.

Internationally Tested Self Active Ese Lightning Rod 60μS Long Life 8

5m installation height is the standard installation height - mostly used by clients

 

Max Radius Protection of TSTLP SMT-ESE60 as per different protection levels:

Level 1:   80 meters radius coverage.

Level 2:   90 meters radius coverage.

Level 3: 105 meters radius coverage.

Level 4: 120 meters radius coverage.


It's highly recommended that Protection Level 1 to be used as highest protection for the objects protected, which most clients do the same.


The protection levels I, II, III or IV (as calculated in NF C 17-108 or EN62305-2) and the height of the TSTLP ESE lightning rod blow the structure to be protected
(H, defined by NF C 17-102 as a minimum 2m).
 
Internationally Tested Self Active Ese Lightning Rod 60μS Long Life 9
 

  • ESE Lightning Rod Protection of high rise buildings (height greater than 60 m)

Additional protection against direct lightning strike for the highest 20% of the structure height for buildings greater than 60 m or any point above 120 m, using ESE lightning rod or any other means must be implemented at each façade wall according to a valid standard. Furthermore a minimum of 4 Down conductors, interconnected by a ring conductor when applicable, shall be used, distributed along the perimeter and if possible at each angle of the building.
NOTE: in general the risk due to the lateral flashes is low because only a few percent of all flashes to tall structures will be to the side and moreover their parameters are a lot lower than those of flashes to the top of structures.

 

  • Order & Packing

Internationally Tested Self Active Ese Lightning Rod 60μS Long Life 10
 

  • TSTLP/SMT-ESE60 Early Streamer Emission Air Terminal for miliary airport direct lightning protetion in Europe

Internationally Tested Self Active Ese Lightning Rod 60μS Long Life 11

 

  • TSTLP/SMT-ESE60 ese lightning rod for KH project "Tiger Show" lightning strike protection.

Internationally Tested Self Active Ese Lightning Rod 60μS Long Life 12

 

More Overseas Project Referenceshttp://www.tslpro.com/references-4.html

 

Internationally Tested Self Active Ese Lightning Rod 60μS Long Life 13

 

FAQ:

1 - Is your company manufacturer or distributor or tradig company ?

   - Instead of lightning rod distributors / trading company, we're professional & reliable Surge Protection Device

     ESE Lightning Rod Manufacturer.

 

2 - Is TSTLP your brand ?

   - Yes, TSTLP is our official registered brand .

 

3 - Can I trust your factory & products ?

A: Sure, we’re ISO 9001:2015 HIGH-Quality Management System Certified Lightning Surge Protection Manufacturer in Guangdong, China

B: We’re using company bank accounts for receiving international payment and company e-mails for communications for high reliability.

C: We have great MANY real OVERSEAS project/installation references, which c/b tracked on line from our website.

D: Patented & tested by Offical Accredited (High-Voltage) Laboratories, Authorized Test Reports / Certificates available.

E: You’re welcome to visit our factory.

 

4-  I saw some model num or discharge time from others in their website is higher, why your biggest model shows 60μs ?

TSTLP SMT-ESE60's Delta T tested in Shanghai is 66.33μs and ΔT = 64.9 ± 4.6% at ICMET in Romania - Europe. 

According to latest standard NF C 17-102:2011, for tested results of ΔT higher than 60μs, the early streamer emission time will be considered as ΔT = 60μs

 

5 - Why choose our TSTLP ESE lightning rod

A: ISO 9001:2015 HIGH-Quality Management System Certified Lightning Protection Manufacturer.

B: Patent Rights Available, unique for promotion & interests protection.

C: Successfully tested at ACCREDITED labs in ShanghaiSpain & Romania -  Europe according to the popular French NF C 17-102:2011 Annexe C & Spanish UNE 21.186:2011 standards for your full satisfaction. Cover Pages of Test Reports with CE, CMA & CAL, Romania-RENAR, Spainish ENAC & ilac-MRA marks (ilac-MRA is the most important recognition for international acceptance). TSTLP ESE Lightning Rods ~ No.1 among domestic brands, TOP 10 worldwide

 

As far as we're concerned, among all the domestic ESE products, ONLY brand TSTLP Active ESE Lightning Rod has passed above mentioned standards (especially for the E.S.E. Time Test) in Accredited Labs in Shanghai & Europe,  while Beijing Test Labs are NOT accredited by CMA/CAL/CNAS/ilac-MRA to do above mentioned popular standards..


Download PDF 2021 TSTLP ESE Lightning Rod Catalog @  https://drive.google.com/file/d/1Ok_HQ03COLvV4JhIK3ijjUv2-RYUNbfK/view?usp=sharing

 

PDF 2021 Datasheet DOWNLOAD - TSTLP SMT-ESE60.pdf
 

PDF Catalog Download - TSTLP-ESE Tester (Black).pd...

 

PDF Catalog Download - Portable TSTLP-ESE Tester....


Relative Product Name: ese lightning conductor, ese air terminal, ese lightning arrester

Contact Details
TS Lightning Protection Co.,Limited

Contact Person: Franklin

Tel: +86-13926098193

Fax: 86-20-28819702-27806

Send your inquiry directly to us (0 / 3000)

Other Products