Start Future From Safety
NO LIGHTNING ACCIDENT IS ALLOWED
Place of Origin: | Guangzhou |
Brand Name: | TSTLP |
Certification: | CE Compliance |
Model Number: | TS-EX24 |
Minimum Order Quantity: | Negotiable |
---|---|
Price: | Negotiable if good quantity |
Packaging Details: | By standard export box/carton |
Delivery Time: | Around 7 working days upon receipt of payment |
Payment Terms: | 100% TT / LC / Western Union / MoneyGram / WeChat Transfer / Alipay / Wanda Money Transfer / Cash ahead |
Supply Ability: | 2000 sets/month |
Un: | 24V | Uc: | 32V- / 22.5~ |
---|---|---|---|
Iimp: | 1.5kA | IL: | 0.55A |
In: | 10kA | FG: | 67MHz |
Enclosure Material: | Stainless Steel Case | Compliance: | IEC-61643-21 / GB18802.21 / YD/T 1542 |
High Light: | din rail surge protector,electrical surge protection devices |
Hazardous area surge protection device for 4-20mA measuring control & bus system
Installed at LPZ OB-2 or higher inside the control equipment, the built-in cable connected with the control equipment’s wiring terminal. TS-24 hazardous area surge protection device is available to apply in intrinsically safe circuit in hazardous areas and 4-20mA measuring control system and bus system.
Model Number | TS-EX24 | |
Normal Voltage | Un | 24V- |
Rated voltage (max. continuous voltage) | Uc |
32V- 22.6V ~ |
Lightning impulse current (10/350) | Iimp | 1.5kA |
Normal current | IL | 0.55A |
Nominal discharge current (8/20) | In | 10kA (per line); 10kA(total) |
Voltage protection level at In | Up | ≤ 58V (line/line); ≤ 1700V (line/PG) |
Voltage protection level at 1kV/μs | Up | ≤ 50V (line/line); ≤ 1200V (line/PG) |
Bandwidth | fG | 67MHz |
Capacitance | C | ≤ 25pF (line/line); ≤ 15pF (line/PG) |
Operating temperature range | -40 0C ~ +80 0C | |
Mounting in | M20 x 1.5 screws | |
Connection (input / output) | 1.3 mm x 250mm length of the connecting lead | |
Earthing via | Connecting lead | |
Enclosure material | Stainless steel case | |
Compliance | IEC-61643-21, GB18802.21, YD/T 1542 |
Installation Instruction
Regularly inspect the operating status, especially after lightning. Once the communication is off, electrician should check/replace the SPD.
|
INSTALLATION DIAGRAM
|
WARNING:
|
PDF Catalog Download - TS-EX24 SPD for Hazardous ...
Tag: hazardous area surge protection, hazardous area surge protection device
Contact Person: Franklin
Tel: +86-13926098193
Fax: 86-20-28819702-27806
Internationally Tested Self Active Ese Lightning Rod 60μS Long Life
Material - Tested Active Ese Lightning Rod As Per UNE21.186 Mirror - Shine Housing
Rustproof Air Terminal Ese Lightning Arrester For Homes / Barn / Villa / Chimney
Early Streamer Emission Ese Lightning Rod On Buildings NF C 17-102 Standard
120kA Type Surge Protection Device CE Compliance For Electrical Switchboards
CE Approved 100kA Type 1 Surge Protection Device For Electrical Panel Protection
TTY / V11 / RS232 / RS485 / RS422 Surge Protection Device Fire Alarm Surge Protection
Data 4 20mA Surge Protection Device 5v - 110v Available 12x64.5x92mm
CE Approval 7 Digits Lightning Strike Counter Exchangeable 3V Battery Support
Stable 3 Digits ESE Lightning Strike Counter Complies With CE Certificate
Long Life Digital Display Lightning Strike Counter Easy Installation
Power Backup 4 Digits Lightning Stroke Counter With Power Line Surge Protector